KiCad 8.0 PCB Editorcount This sets the minimum acceptable number of thermal relief spokes connecting a pad to a zone. A DRC violation will be generated if this constraint is violated. Include stackup height in track length or via size to a different value from that defined in the Net Classes section will not result in a DRC violation. To restrict track width or via size to specific values, use Custom Rules. The lower portion footprint or a selection of footprints, ignoring any connected track segments that are not selected. No DRC checking is done when moving footprints with the Move command, although any footprint courtyards that0 码力 | 205 页 | 6.78 MB | 1 年前3
KiCad PCB Editor 4.0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 11.2 Final DRC test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . by regenerating the netlist and reading it in pcbnew again. Pcbnew provides a design rules check (DRC) tool which prevents track and pad clearance issues as well as preventing nets from being connected to page Find footprint or text. Netlist operations (selection, reading, testing and compiling). DRC (Design Rule Check): Automatic check of the tracks. Selection of the working layer. Selection of0 码力 | 153 页 | 3.10 MB | 1 年前3
KiCad PCB Editor 4.0by regenerating the netlist and reading it in pcbnew again. Pcbnew provides a design rules check (DRC) tool which prevents track and pad clearance issues as well as preventing nets from being connected to page Find footprint or text. Netlist operations (selection, reading, testing and compiling). DRC (Design Rule Check): Automatic check of the tracks. Selection of the working layer. Selection of provides display and control options that affect Pcbnew’s interface. Turns DRC (Design Rule Checking) on/off. Caution: when DRC is off incorrect connections can be made. Turn grid display on/off Note:0 码力 | 268 页 | 2.81 MB | 1 年前3
KiCad PCB Editor 5.1by regenerating the netlist and reading it in pcbnew again. Pcbnew provides a design rules check (DRC) tool which prevents track and pad clearance issues as well as preventing nets from being connected to page Find footprint or text. Netlist operations (selection, reading, testing and compiling). DRC (Design Rule Check): Automatic check of the tracks. Selection of the working layer. Selection of provides display and control options that affect Pcbnew’s interface. Turns DRC (Design Rule Checking) on/off. Caution: when DRC is off incorrect connections can be made. Turn grid display on/off Note:0 码力 | 279 页 | 3.02 MB | 1 年前3
KiCad PCB Editor 5.1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 11.2 Final DRC test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . by regenerating the netlist and reading it in pcbnew again. Pcbnew provides a design rules check (DRC) tool which prevents track and pad clearance issues as well as preventing nets from being connected to page Find footprint or text. Netlist operations (selection, reading, testing and compiling). DRC (Design Rule Check): Automatic check of the tracks. Selection of the working layer. Selection of0 码力 | 166 页 | 3.28 MB | 1 年前3
KiCad PCB Editor 7.0
count This sets the minimum acceptable number of thermal relief spokes connecting a pad to a zone. A DRC violation will be generated if this constraint is violated. Include stackup height in track length or via size to a different value from that defined in the Net Classes section will not result in a DRC violation. To restrict track width or via size to specific values, use Custom Rules. The lower portion footprint or a selection of footprints, ignoring any connected track segments that are not selected. No DRC checking is done when moving footprints with the Move command. There is a reference point for the0 码力 | 129 页 | 7.75 MB | 1 年前3
KiCad 7.0 Reference manualtwo consistent. When the board layout is complete and the board has passed the Design Rules Check (DRC), fabrication outputs are generated so that the board can be manufactured by a PCB fabricator. 7 when footprints within them are moved. Zones are refilled by manually filling them and when running DRC. Make sure zone fills are up-to-date before generating fabrication outputs. Sometimes filled zones Checking Design Rule Checking is the layout equivalent of Electrical Rule Checking for the schematic. DRC looks for design mistakes like mismatches between the schematic and layout, copper regions that have0 码力 | 52 页 | 2.24 MB | 1 年前3
Getting Started in KiCad 6.0two consistent. When the board layout is complete and the board has passed the Design Rules Check (DRC), fabrication outputs are generated so that the board can be manufactured by a PCB fabricator. 7 when footprints within them are moved. Zones are refilled by manually filling them and when running DRC. Make sure zone fills are up-to-date before generating fabrication outputs. Sometimes filled zones Checking Design Rule Checking is the layout equivalent of Electrical Rule Checking for the schematic. DRC looks for design mistakes like mismatches between the schematic and layout, copper regions that have0 码力 | 54 页 | 2.41 MB | 1 年前3
Getting Started in KiCad 8.0two consistent. When the board layout is complete and the board has passed the Design Rules Check (DRC), fabrication outputs are generated so that the board can be manufactured by a PCB fabricator. 7 when footprints within them are moved. Zones are refilled by manually filling them and when running DRC. Make sure zone fills are up-to-date before generating fabrication outputs. Sometimes filled zones Checking Design Rule Checking is the layout equivalent of Electrical Rule Checking for the schematic. DRC looks for design mistakes like mismatches between the schematic and layout, copper regions that have0 码力 | 53 页 | 2.32 MB | 1 年前3
KiCad PCB Editor 6.0or via size to a different value from that defined in the Net Classes section will not result in a DRC violation. To restrict track width or via size to specific values, use Custom Rules. Custom Rules outputs. KiCad will check that zones have been updated and warn you before generating outputs or running DRC when zones have not yet been refilled. To draw a zone, click the Add Filled Zone tool ( ) on the right be used to assign a specific name to a zone. This name can be used to refer to the zone in custom DRC rules. Ctrl Shift Z E 27 Zone priority level determines the order in which multiple zones on a0 码力 | 110 页 | 3.61 MB | 1 年前3
共 22 条
- 1
- 2
- 3